Extract from GAS INSTALLATION CODE AG 601 - 2002
5.2.7 Combustible surfaces - Temperature limitation
An appliance shall be installed such that the surface temperature
of any nearby combustible surface will not exceed 50ºC above
ambient.
NOTES:
- Type A appliances installed to manufacturer's instructions
should satisfy the intent of this requirement.
- Care should be taken where a combustible surface is covered
by a non-combustible material. EG. covering a combustible surface
with stainless steel will not prevent heat transfer and in some
circumstances a hazardous situation could arise.
5.12.1.2 Protection of a combustible surface near
a cooking appliance
The protection required by Clause 5.12.1.1 shall ensure the surface
temperature of the combustible surface does not exceed 50ºC
above ambient.
NOTE:
The fixing of 5mm thick ceramic tiles to the surface or attaching
fire resistant material to the surface and covering with sheet
metal with a minimum thickness of 0.4mm would satisfy this requirement.
PLEASE NOTE
The above extract from the gas installation code.
When a splashback is to be installed with a gas cooktop the
regulations stated above must be adhered to. |